The HT-P V2 series Hipot Testers emerges from the redesigned HT-P series, offering new long life buttons, robust design, lighter and cleaner appearance. Performs the Ground Continuity Test with a fix Pass/Fail point of 2.93Ω, 2800V DC Hipot Test, Neutral/Hot to Ground Leakage current test up to 5mA DC. Easy to use and connect. Ships complete with cables, manual, Calibration Certificate and Calibration Data Log Copy. Made in the USA. Calibration and repair services available. Not sure – contact us!
HT-2800P V2:
SKU: 00-HT2800PV2Hipot Tester
2800Vdc @ 5mA
2800Vdc @ 5mA
$1,560.00
Hipot Tester, performs the Ground continuity, Leakage and breakdown test.
Features
- High precision leakage current, duration and ground continuity settings.
- Allows no load setup of leakage current and test dwell times.
- Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing.
- Leakage currents can be set from 1-5mA dc in 0.1mA increments.
- Dwell times can be set from 1-60 seconds in 1 second increments.
- Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
- Small and light. 9.25″ wide x 4.75″ high x 10″ deep. 11 lbs. But rugged enough to test manufactured housing.
- Ground continuity check is defeatable for testing two-wire products.
- Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
- Optional J2 and J3 cords allow connection of pigtail power leads.
- Simple test outcome judgement. Green lights mean pass – red lights mean fail. Failing tests sound a buzzer as well.
- Ready for your UL Inspector out of the box.
- NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
- Operation Instructions are printed on the rear panel for easy reference.
- In-depth testing. Both true Arc Detection and Leakage Current circuits test the product to find problems.
- RED lights and a buzzer leave no question if a failure has occurred.
- Expandable for TUV/European Agency Testing. Can be connected to our GF-30AC-T Ground Bond Tester with optional TEST-LINK™.
- Easy shift-by-shift Function Test. Compatible with our Patented function checker HTT-1.
Specifications
TESTING CIRCUITRY
Test Type: DC.
Max. Output Voltage: 2800Vdc.
Leakage Current: 1-5mAdc, 0.1mA increments.
Breakdown Detect: Independent High Frequency Circuit (50KHz–500KHz).
Transformer Power: <500VA.
Leakage Current Detect: Independent Low Frequency Circuit.
Ramp Time Range: 1-5 Seconds.
Test Time Range: 1-60 Seconds.
Discharge Time: <1.3s for max DC at open circuit.
Display: 4 Digits LED Display.
Voltage Meter Accuracy: ±2%
Leakage Accuracy: ±0.1mA.
Ground Continuity: 2.93Ω, Defeatable.
Duty Cycle: 100%
Pass/Fail Repeatability: ±3%
ELECTRICAL
Rated Input Voltage: 120Vac.
Frequency: 60Hz.
Fuse: 1A, 250V, time delay, 5x20mm.
SAFETY
Safety Interlock: 2-pin terminal block on rear panel; shorted for operation. (Optional)
Output Voltage Indicator: Front panel meter directly connected to High Voltage.
Failure Indicator: Visual, provided by red LED’s.
Audible, provided by buzzer.
Test automatically terminated on failure.
OUTPUTS
NEMA 5-15R: High Voltage output for easy DUT connection.
RETURN: 4mm Socket (XEF-1RR), 1000V, CAT IV, 24A, Black.