HT-20KVP AC:

SKU: 00-HT20KP ac

Hipot Tester
20KVac @ 5mA

$6,250.00

Options

Hipot Tester <br />20KVac @ 5mA $6,250.00

Designed & Built in the USA

  • 1-Year Warranty
  • 100% Secure Checkout
Guaranteed Safe Checkout

The HT-20kVP AC tester is a 20KVac hipot tester with Voltage and Leakage current displays for easy output monitoring.

Offers defeatable settings and adjustments on the front panel.

Easy to set up and use. Ships complete with cables, manual, Calibration Certificate and Calibration Data Log Copy.. Ships complete with cables, manual, and Calibration Certificate. Made in the USA. Calibration and Repair services available. Not sure – contact us!

Features

• Fast accurate results.
• Microcontroller Technologies.
• One button test, easy to setup.
• LED’s indicate test progress.
• Upon failure, the buzzer sounds, and testing is terminated.
• Output voltage, leakage limit, volt ramp-up time and test duration controls on front panel.
• Voltage ramp, arc detection and test timer are defeatable.
• Designed for product development and laboratory use.
• Separate arc detection circuitry.
• Supports PLC interface for complete automated testing with the RI option.
• Main shutdown switch on front panel.
• Ergonomically designed for safety, speed, and efficiency.
• Leads, manual and calibration certificate included.
• ISO17025 Calibration available.
• One year calibration cycle.
• One year warranty.

Specifications

TESTING CIRCUITRY

Test Type: AC.
Max. Output Voltage: 20,000Vac.
Leakage Current: 5mA continuous duty / 12.5mA 25% duty.
Breakdown Detect: Independent High Frequency Circuit (50KHz–500KHz).
Transformer Power: <500VA.
Leakage Current Detect: Independent Low Frequency Circuit.
Discharge Time: <7ms
Ramp Time Range: 1-5 Seconds.
Test Time Range: 1-60 Seconds.
Display: 4 Digits LED Display.
Voltage Meter Accuracy: ± 0.1KVac full scale.
Leakage Accuracy: ±0.1mA full scale.
Duty Cycle: 100%; Continuous.
Pass/Fail Repeatability: ±3%

ELECTRICAL
Rated Input Voltage: 120Vac. / 220,230V optional
Frequency: 50/60Hz.
Fuse: 2A / 1A, 250V, time delay, 5x20mm.

SAFETY
Safety Interlock: 2-pin terminal block on rear panel; shorted for operation. (Optional)
Output Voltage Indicator: Front panel meter directly connected to High Voltage.
Failure Indicator: Visual; provided by red LED’s, Audible; provided by buzzer.
Test automatically terminated on failure.

OUTPUTS
HV: High Voltage output.
RETURN: 4mm Socket (XEF-1RR), 1000V, CAT IV, 24A, Black.