HT-10KVPAC Hipot / Dielectric Tester with microcontroller technology for ease of use. AC output 0-10,000Vac @ 10mA. Ships complete with cables, manual, and Calibration Certificate. Made in the USA. Calibration and Repair services available. Not sure – contact us!
Specifications
TESTING CIRCUITRY
Test Type: AC.
Max. Output Voltage: 10,000Vac.
Leakage Current: 10mAac, 0.1mA increments.
Breakdown Detect: Independent High Frequency Circuit (50KHz–500KHz).
Transformer Power: <500VA.
Leakage Current Detect: Independent Low Frequency Circuit.
Ramp Time Range: 1-5 Seconds.
Test Time Range: 1-60 Seconds.
Display: 4 Digits LED Display.
Voltage Meter Accuracy: ± 0.1KVac full scale.
Leakage Accuracy: ±0.1mA full scale.
Duty Cycle: 100%; Continuous.
Pass/Fail Repeatability: ±3%
ELECTRICAL
Rated Input Voltage: 120Vac. 220,230V optional
Frequency: 50/60Hz.
Fuse: 2A, 250V, time delay, 5x20mm.
SAFETY
Safety Interlock: 2-pin terminal block on rear panel; shorted for operation. (Optional)
Output Voltage Indicator: Front panel meter directly connected to High Voltage.
Failure Indicator: Visual; provided by red LED’s, Audible; provided by buzzer.
Test automatically terminated on failure.
OUTPUTS
HV: High Voltage output.
RETURN: 4mm Socket (XEF-1RR), 1000V, CAT IV, 24A, Black.